Plumb

Calculator · free

Storm water runoff calculator

Enter the drained area, the type of surface and the design rainfall. The calculator gives the peak runoff with the rational method, the volume of a 15-minute storm and the smallest PVC pipe that carries it at the slope you choose.

Calc. 12 — Storm water

How to use it

  1. Enter the area that drains to the pipe: roof plan area, paving or the whole yard.
  2. Choose the surface. Roofs shed almost all the rain (C 0.9), lawns much less.
  3. Enter the design rainfall intensity for your location and the pipe slope.

Worked example

A 150 m² roof (C 0.9) under a 150 L/s per hectare storm gives Q = 0.9 × 150 × 150 ÷ 10,000 = 2.0 L/s. A 15-minute storm then delivers about 1.8 m³ of water, which is a useful size for a soakaway or a rain tank.

Choosing the design rainfall

Short, intense storms govern small catchments such as roofs and yards. Local rainfall data give the intensity for a duration and a return period; 150–250 L/s·ha (54–90 mm/h) is common for 10–15 minute storms in temperate climates. Use a higher value for gutters and downpipes, where an overflow causes damage.

Frequently asked questions

What is the rational method?

Q = C × i × A: the runoff coefficient of the surface times the rainfall intensity times the area. It suits small catchments up to a few hectares.

How much water comes off a roof?

About 0.9 litres for every millimetre of rain on every square metre of roof. A 100 m² roof gives 900 litres from a 10 mm shower.

What size drain pipe do I need for a roof?

It depends on the area, the rainfall and the slope; for a house roof under 200 m² a 110 mm PVC drain at 1–2% usually has spare capacity.